ENSYS MOTORS AND DRIVES CO., LTD.
- 636/6 Soi Ramkhamhaeng 39 Pracha Uthit Rd.,
- +66 (0) 2 934 5820
- sales@ensys.co.th
Series | KA3 | Voltages | 3 – 11 kV line and inverter operation |
Frame size | 315 – 500 | Frame construction | Cast iron |
Power output | 180 – 1600 kW | Degree of protection | IP55, IP56, IP65, IP66 |
Mounting arrangments | B3, V1, B35 | Temperature class | 155 (F) according to 130 (B) |
Number of poles | 2 – 16 | Cooling method | IC411 |
Bearings | Rolling elements or sleeve bearings | Certificates | CE |
KE2 motors are characterized by a rugged design, high effciency, reliability and ease of maintenance. They are available to all customers requirements. Schorch ex motors are suitable for the most severe site and operational conditions.
Series | KE2 | Ex protection level | Ex II 2 G Ex e IIC T3 Gb |
Frame size | 315 – 560 | Voltages | 3 – 11 kV line |
Power output | 160 – 1.330 kW | Frame construction | Cast iron |
Mounting arrangments | B3, B5, B35, V1 | Degree of protection | IP55, IP56, IP65 |
Number of poles | 2 – 16 | Temperature class | 155 (F) according to 130 (B) |
Certificates | ATEX, IEC-EX | Cooling method | IC411 |
KD2 motors are characterized by a rugged design, high effciency, reliability and ease of maintenance. They are available to all customers requirements. Schorch ex motors are suitable for the most severe site and operational conditions.
Series | KD2 | Ex protection level | Ex d IIB or C T4 Gb and Ex de IIB or C T4 Gb |
Frame size | 355 – 500 | Voltages | 3 – 11 kV line and inverter operation |
Power output | 185 – 1.320 kW | Frame construction | Cast iron |
Mounting arrangments | B3, V1, B35 | Degree of protection | IP55, IP56, IP65 |
Number of poles | 2 – 16 | Temperature class | 155 (F) according to 130 (B) |
Certificates | ATEX, IEC-EX | Cooling method | IC411 |
KV motors are characterized by a rugged design, high effciency, reliability and ease of maintenance. They are available to all customers requirements. Schorch ex motors are suitable for the most severe site and operational conditions.
Series | KV | Voltages | 2,3 – 15kV line and inverter operation |
Frame size | 400 – 1.200 | Frame construction | Fabricated steel |
Power output | 160 – 17.000kW | Degree of protection | IP55, IP65 |
Mounting arrangements | B3, V1 | Temperature class | 155 (F) according to 130 (B) |
Number of poles | 2 – 24 | Cooling method | IC611 |
Bearings | Roling elements and sleeve bearings | Certificates | CE |
KU motors are characterized by a rugged design, high effciency, reliability and ease of maintenance. They are available to all customers requirements. Schorch ex motors are suitable for the most severe site and operational conditions.
Series | KU | Voltages | 2,3 – 15kV line and inverter operation |
Frame size | 400 – 1.200 | Frame construction | Fabricated steel |
Power output | 160 – 17.000kW | Degree of protection | IP55, IP65 |
Mounting arrangements | B3, V1 | Temperature class | 155 (F) according to 130 (B) |
Number of poles | 2 – 24 | Cooling method | IC81W |
Bearings | Roling elements and sleeve bearings | Certificates | CE |
KU motors are characterized by a rugged design, high effciency, reliability and ease of maintenance. They are available to all customers requirements. Schorch ex motors are suitable for the most severe site and operational conditions.
Series | KU | Ex protection level |
Ex II 3G Ex nA IIC T3 Ex II 2G Ex e IIC T3 Gb Ex II 2G Ex px e ib IIC T3 Gb |
Frame size | 400 – 1.200 | Voltages | 3 – 15 kV line and inverter operation |
Power output | 160 – 17.000 kW | Frame construction | Fabricated steel |
Mounting arrangments | B3, V1 | Degree of protection | IP55, IP65 |
Number of poles | 2 – 24 | Temperature class | 155 (F) according to 130 (B) |
Certificates | ATEX, IEC-EX | Cooling method | IC81W |
KV motors are characterized by a rugged design, high effciency, reliability and ease of maintenance. They are available to all customers requirements. Schorch ex motors are suitable for the most severe site and operational conditions.
Series | KV | Ex protection level |
Ex II 3G Ex nA IIC T3 Ex II 2G Ex e IIC T3 Gb Ex II 2G Ex px e ib IIC T3 Gb |
Frame size | 400 – 1.200 | Voltages | 3 – 15 kV line and inverter operation |
Power output | 160 – 17.000 kW | Frame construction | Fabricated steel |
Mounting arrangments | B3, V1 | Degree of protection | IP55, IP65 |
Number of poles | 2 – 24 | Temperature class | 155 (F) according to 130 (B) |
Certificates | ATEX, IEC-EX | Cooling method | IC611 |
Series | PZ | Voltages | 3 – 13,8 kV |
Frame size | 355 – 800 | Frame construction | Fabricated steel |
Power output | 200 – 9.000 kW | Degree of protection | IP55, IP65 |
Mounting arrangments | B3, V1 | Temperature class | 155 (F) according to 130 (B) |
Efficiency class | Cooling method | IC611 | |
Number of poles | 2 – 10 | Certificates | CE |
Series | KR | Ex protection level | II 3G Ex nA II T1-T4 Gc |
Frame size | 500 – 1700 | Voltages | 3 – 15 kV line and inverter operation |
Power output | 160 – 17.000 kW | Frame construction | Fabricated steel |
Mounting arrangments | B3, V1 | Degree of protection | IP55, IP65 |
Number of poles | 2 – 24 | Temperature class | 155 (F) according to 130 (B) |
Certificates | ATEX, IEC-EX | Cooling method | IC511 |
Series | KR | Ex protection level | Ex d IIB or C T4 Gb and Ex de IIB or C T4 Gb |
Frame size | 500 – 1500 | Voltages | 3 – 11 kV line and inverter operation |
Power output | 160 – 13.200 kW | Frame construction | Fabricated steel |
Mounting arrangments | B3, V1 | Degree of protection | IP55, IP65 |
Number of poles | 2 – 24 | Temperature class | 155 (F) according to 130 (B) |
Certificates | ATEX, IEC-EX | Cooling method | IC511 |